title: Accuracy of Linear Measurements of Ultra-low Dose Cone Beam Computed Tomography and Digital Panoramic Radiography
nct_id: NCT03719235
overall_status: UNKNOWN
phase: NA
sponsor: Cairo University
study_type: INTERVENTIONAL
primary_condition: Cone Beam Computed Tomography
countries: Egypt
canonical_url: "https://parkinsonspathways.com/agent/trials/NCT03719235.md"
clinicaltrials_gov: "https://clinicaltrials.gov/study/NCT03719235"
ct_last_update_post_date: 2018-10-25
last_seen_at: "2026-05-12T07:34:40.789Z"
source: ClinicalTrials.gov (mirrored, no enrichment)
---
# Accuracy of Linear Measurements of Ultra-low Dose Cone Beam Computed Tomography and Digital Panoramic Radiography

**Official Title:** Accuracy of Linear Measurements of Ultra-low Dose Cone Beam Computed Tomography and Digital Panoramic Radiography Performed on Mandibular Anaesthetic Landmarks Versus Real Mandibular Measurements

**NCT ID:** [NCT03719235](https://clinicaltrials.gov/study/NCT03719235)

## Key Facts

- **Status:** UNKNOWN
- **Phase:** NA
- **Study Type:** INTERVENTIONAL
- **Target Enrollment:** 10
- **Lead Sponsor:** Cairo University
- **Conditions:** Cone Beam Computed Tomography
- **Start Date:** 2018-07-10
- **Completion Date:** 2020-09-10
- **CT.gov Last Update:** 2018-10-25

## Brief Summary

measurements performed directly on dry mandibles will be compared with measurements obtained from CBCT( ultra-low dose) scans and Digital panoramic radiography.

## Detailed Description

Mandibular anaesthetic landmarks will be identified on each dry mandible and will be marked using gutta percha.

The ten human dry mandibles will be submitted for:

1. Digital Panoramic Radiography. Panoramic radiographs will be obtained using the SOREDEX CRANEX™ 3Dx unit. The exposure parameters will be 8Ma, 63kVp and 16.4 sec exposure time.
2. Cone Beam Computed Tomography (CBCT). SOREDEX CRANEX™ 3Dx unit will be used in this study. Images will be acquired at a single rotation. SOREDEX® MiniDose parameters will be used. The exposure parameters will be 3.2 Ma, 90kVp and 2.3 sec exposure time to take the advantage of 3D data in dose sensitive cases like children, or reduce the radiation dose for the patient.

The real linear measurements will be measured in millimeter on dry mandibles using digital caliper and will be compared with measurements obtained from both techniques.

Images will be evaluated by two experienced radiologists of ten years of experience. Each one will evaluate the images separately twice with a period of two weeks in-between the two reading sessions. The researcher will measure out the real linear measurements on the dry mandibles using digital caliper.

## Eligibility

- **Minimum age:** 10 Years
- **Maximum age:** 70 Years
- **Sex:** ALL
- **Healthy Volunteers:** No

```
Inclusion Criteria:

* age 10 to 70 years
* no gender nor race predilection
* Either dentulous or edentulous are acceptable.

Exclusion Criteria:

* fractures
* pathology
```

## Arms

- **column** (OTHER) — ultra-low dose CBCT versus digital panoramic radsiography

## Interventions

- **CBCT** (OTHER) — ultra-low dose CBCT

## Primary Outcomes

- **assessment of diagnostic accuracy of linear measurements** _(time frame: within 2 years)_ — measurements made on dry mandibles will be compared with measurements obtained from CBCT scans \& digital panoramic radiography

## Locations (1)

- Cairo University, Cairo, Egypt — _RECRUITING_

## Recent Field Changes (last 30 days)

- `locations.cairo university|cairo||egypt` — added _(2026-05-12)_
- `status.overallStatus` — added _(2026-05-12)_
- `status.primaryCompletionDate` — added _(2026-05-12)_
- `status.completionDate` — added _(2026-05-12)_
- `status.lastUpdatePostDate` — added _(2026-05-12)_
- `design.phases` — added _(2026-05-12)_
- `design.enrollmentCount` — added _(2026-05-12)_
- `eligibility.criteria` — added _(2026-05-12)_
- `eligibility.minAge` — added _(2026-05-12)_
- `eligibility.maxAge` — added _(2026-05-12)_
- `eligibility.sex` — added _(2026-05-12)_
- `outcomes.primary` — added _(2026-05-12)_
- `armsInterventions.arms` — added _(2026-05-12)_
- `armsInterventions.interventions` — added _(2026-05-12)_
- `sponsor.lead` — added _(2026-05-12)_
- `results.hasResults` — added _(2026-05-12)_

---

*Canonical: https://parkinsonspathways.com/agent/trials/NCT03719235.md*  
*Source data (authoritative): https://clinicaltrials.gov/study/NCT03719235*  
*This page is a raw mirror with no AI summary, no editorial enrichment, and no Parkinson's-specific filtering.*